BLDC (PMSM) end turns and torque production

Jan 2020 update: I have removed the discussion of end turns in iron-core motors from this post as I have since learned that the arguments used were flawed. I will address this topic in my next post.

End turns are not considered when calculating the torque of a hobbyist grade BLDC (PMSM) electric motor. This post explores why.

1.End turns and BLDC motors

End turns are the region of a BLDC motor's windings which extend out from the slots at either end of a motor.
Current supplied to a motor passes from one slot to the next via the end turns. However, end turns are not typically considered when calculating the torque produced by a BLDC motor in 2D FEA software packages such as FEMM.

Although end turns can be ignored when it comes to calculating torque, they do contribute to the resistance of the windings. It is therefore ideal to have the end turns be as short as possible when designing a motor so as to improve motor efficiency by minimising ohmic losses in the windings.

Electric motors with concentrated windings, like those found in most hobbyist outrunners, have shorter end turns than those used in motors with distributed windings. Motors that use concentrated windings are therefore more efficient in some use cases, such as in high torque density, low-speed applications. However, as only a limited number of slot and pole combinations are available for concentrated windings they are not suitable for all use cases.

2. Torque generation and end turns in core-less motors

To understand why end turns are not considered when calculating the torque output of a BLDC motor let us consider a simplified scenario. In the diagram below a single turn copper wire is placed inside a homogenous magnetic field provided by permanent magnets placed above and below the wire. The magnets are arranged so that the applied field direction is different for either side of the wire.

This situation is an analogous to core-less electric motors which have no ferromagnetic material in the stator. If a current flows through the wire then a Lorentz force is produced on that wire as described by:

Force = Magnetic field `\times`Current`\times` Conductor length

where the magnetic field (B) is supplied from the magnets, the current (I) is that flowing through the wire of a given length (L). Looking at this setup from the top down we see the following.

It is clear that a Lorentz force is only generated on the wire which is located between the magnets, which is analogous to the wire located within the slots of a BLDC motor. The parts of the wire which extend outside of the magnets are not exposed to a magnetic field and so the force generated is zero. This situation is the same for end turns in a BLDC motor, and so is ignored by FEA software packages.

However, for the sake of argument, let us also consider a situation where the magnets could be made long enough that they also covered the end turns. In this situation, a force is generated by the end turns. However, this force is tangential to that generated by the wires in the 'slots' and so would not contribute to the production of useful torque within a motor. This force would also be mostly cancelled out as can be seen from below.

Another arrangement I have seen used by DIY motor makers is to take round coils and magnets and arrange them to make an axial flux motor or generator.



While this approach will work, it is also inefficient since the force produced on the wires is always tangential to the flow of current and so a significant fraction of the force is not available to useful work.

Note that although all of the above examples are for core-less motors, the situation is unchanged for iron cored motors.

In my next post, the concept of flux linkage will be explored and used to understand why end turns still do not contribute to flux in conventional iron-core motors.

4. Conclusion

End turns in air-core motor designs are not considered in the calculation of torque as they are either outside of the region exposed to the permanent magnet's magnetic field or the force generated is in the wrong direction.

Equations were produced in this post with the help of arachnoid.com. If you have noticed any errors in the above article then please let me know.

Sunday, December 23, 2018

Why most hobby grade BLDC out runners are actually permanent magnet synchronous motors (PMSM)

Look anywhere online for a brushless direct current (BLDC) electric motor and you will likely find something that looks like the out-runner shown below:
A hobby grade 'BLDC' motor
However, it turns out this is technically not a BLDC motor. By most definitions, it is actually a permanent magnet synchronous motor (PMSM). If you own a similar looking out-runner style hobby motor then you too may have a PMSM.

This post will briefly cover the difference between a BLDC motor and a PMSM and when this difference matters.

BLDC vs PMSM

BLDC and PMSM have a lot in common. Neither have brushes, both have permanent magnets on the rotor and have an armature on the stator. Where they differ is in how the magnetic field produced by the rotor magnets interacts with the windings of the armature.

Let's consider an 'out-runner' motor of the style shown below.
A cross-sectional view of a 6 slot, 8 pole (6N8P) motor
The movement of the rotor magnets past the stator teeth induces a back EMF (bEMF) into the windings of the armature. When the phase-phase bEMF is plotted with electrical angle (360 electrical degrees = 360 mechanical degrees / no. pole pairs) it may look sinusoidal, trapezoidal, or somewhere in between.


If a motor produces a trapezoidal bEMF then it is considered BLDC motor since this shape is similar to what would be seen from a conventional brushed DC motor. If your motor produces a sinusoidal bEMF then it is generally considered to be a PMSM. 

How to tell if your motor is a BLDC or PMSM? Measure its bEMF

If you have access to an oscilloscope then determining if your motor is a PMSM or a BLDC motor is as simple as measuring across any two phases and spinning the rotor to observe the bEMF shape. This can be done by hand for low kV motors or with the help of a power drill for high kV motors. After doing this for a 12 slot, 14 pole (12N14P) out-runner the following shape was seen:

Back EMF produced by a 12N14P out-runner
IMG_20180423_171938@0,5x.jpg
D5065 270 kV 12N14P brushless out-runner from Odrive Robotics
This motor clearly has a sinusoidal bEMF and so would be considered a PMSM. Repeating this same measurement for a couple of other motors from different manufacturers also yielded the same results.

A sinusoidal bEMF typically means a motor has been wound with distributed windings, where the windings are distributed over many slots, and is more common for large electric motors. Distributed windings are easily spotted by the overlap at the end of the motor.


However, hobby grade brushless motors are almost universally constructed with concentrated windings. It is, therefore, a little surprising that they can produce a sinusoidal bEMF. The reason for a sinusoidal bEMF in the out-runner tested above is apparently related to its 12N14P configuration in combination with its doubly wound concentrated windings. I will explore this in more detail at some point in the future. Note that so far I have only measured 12N14P out-runner style motors and so you may see different results for motors with different slot/pole ratios or for in-runners.

BLDC or PMSM - Does it matter?

Useful torque is produced by an electric motor when you feed in a current waveform to each phase that perfectly opposes the a generated bEMF. Importantly, the shape of the waveform does not matter, so long as it exactly matches the bEMF waveform. For example, consider the torque produced by a PMSM and BLDC motor as seen by the figure below which were taken from James Mavey's excellent masters thesis.
Torque output vs current input for a PMSM (left) and a BLDC (right) motor
When you sum up the current contributions from each phase for the sinusoidal waveform (PMSM) and for the trapezoidal waveform (BLDC) you see the same result; a perfect constant output current, and therefore a constant output torque. Also, in theory at least, both motors should be equally efficient. In reality, even if you could perfectly match the current to the bEMF, the rapid change in flux density seen by the stator in a BLDC motor due to the use of a trapezoidal waveform is likely to induce larger eddy current losses than a comparable sinusoidal PMSM.

The problems begin when you use a motor controller that outputs a current waveform which does not exactly match the bEMF of your motor. Most low-cost hobby grade motor controllers (ESC's) only output a 'six-step 120 degree' current waveform like that shown for the BLDC motor above. Therefore, if you use a PMSM with one of these ESC's it's torque output will be choppy, which creates audible noise, vibration, and will be quite inefficient. Instead, you would ideally use a motor controller which supports field oriented controlled (FOC) and that outputs a sinusoidal current waveform that more closely matches that of your motor.

Furthermore, the trapezoidal bEMF produced by a BLDC motor can vary quite a lot from motor to motor. This means that the current waveform produced by an ESC will never perfectly match the bEMF of a BLDC motor. This means that even if you match a BLDC motor with an ESC you will still have some amount of motor noise, vibration, and decreased efficiency. A PMSM has no such problem since ideally, ever motor produces the same sinusoidal bEMF.

For most hobby applications (e.g. small model planes, boats, and cars) using a PMSM with a conventional six step ESC won't cause any noticeable problems. However, for high-performance applications (e.g. multi-rotors used for cinematography, robotics and EV applications) the reduced noise, vibration and increased efficiency that comes from using a FOC motor controller with a PMSM may mean it's worth the extra investment.

Conclusion

If a motor produces a sinusoidal bEMF then its a PMSM and not a BLDC motor. A PMSM is best driven by a sinusoidal current as this reduces noise, vibration and improves efficiency.

In order to avoid confusion, going forward I will be simply referring to both BLDC and PMSM as brushless permanent magnet synchronous motors (PMSM).

If you have noticed any errors in the above article then please let me know.

Friday, November 23, 2018

Why you don't see tape wound foil conductors used on electric motors

2019 update: Induced eddy currents also contribute significant losses to tape wound motors. This argument has now also been added.

--------------------------------------------------------------------------------------------------------------------

Most electric motors are wound using circular conductors. Some motors are wound using square or rectangular shaped conductors. However, I have never seen a motor with conductors that have a flat, tape-like cross section made from thin foils which are then wound onto a tooth like a roll of sticky tape.


A comparison of the different winding topologies on a stator (black)
That was until this blog post by Shane Colton come to my attention.

This raised a question: Why is it that this style of winding is not used for electric motors?

The short answer: If you wind a thick (i.e. mm) tape wound conductor then you will likely see very large induced eddy current losses in your conductors due to the changing flux they are exposed to. If you use very thin tape wound conductors (i.e. < 0.1 mm thickness) then your copper fill factor will be very poor and you would be better off using a more typical stranded conductor.

Read on to see why.

Potential benefits for using a tape wound foil conductor

First, why use this style of conductors? The benefits may include:
  1. A high copper fill factor. Perfectly stacked round conductors will have a maximum fill factor of ~0.9. Tape wound conductors may improve on this. (This turns out to not be true in most cases)
  2. Ease of winding. A single wide tape may be easier to stack than many small conductors.
  3. High conductor cross section while maintaining a small minimum bend radius. For an equal conductor area, a flat foil will have a much smaller minimum bend radius than a round conductor.
  4. Improved conductor utilisation at high frequency. Due to the skin effect, the centre of a round conductor will carry little current when operating at high electrical frequencies. 
  5. The possibility of improved cooling capacity. The large uniform area of a tape wound conductor may prevent hot spot formation and facilitate better heat conduction to the surface of a winding stack when compared to round wires.

Potential negative consequences for using a tape wound foil conductor

Potential drawbacks to this style of conductors include:
  1. Difficulty in winding a tape wound foil conductor due to the surrounding stator teeth getting in the way.
  2. Stray flux crossing the conductor at right angles (normal to the flat surface of the foil) may significantly increase eddy current losses in a motor.
  3. A high aspect ratio may mean that the electrical insulation occupies a significant fraction of the available area, reducing the copper fill factor.
  4. Due to the proximity effect and the difference in inductance seen by different parts of a tape wound conductor embedded in the slot of a motor, a larger AC current will tend to flow in the region of a conductor closer to the top of a stator slot than the bottom. This will cause a larger than expected AC resistance. See chapter 3.6.7.4 of this book for further details.
Let's look at each of these drawbacks one by one:

1. Difficulty in winding around stator teeth

For small radial flux motors, it may be difficult to automate the winding process. However, segmented radial flux motors or yokeless and segmented armature (YASA) axial flux motors, such as those made by Magnax, Emrax and Yasa, and used by Shane in his blog post, are becoming increasingly common.

A YASA motor with segmented stator teeth.
A YASA axial flux motor has a stator constructed from individual core sections which can each be wound separately before final assembly of the motor. These motors could, therefore, be easily wound with a tape-style conductor.

Magnax axial flux windings and cores 2.jpg
Stator segments wound and ready for assembly of a Magnax motor
Therefore for segmented core motors winding a tape wound foil should pose no problem.

2. Induced eddy current losses

Let's consider the worst-case scenario. Below is a 2D FEMM simulation of an open-ended 30 mm diameter, 80 mm long mild steel rod with 10 turns of conductors added to one end with a current of 6A. Side note: Drawing lines in FEMM is a pain. I recommend using a dedicated CAD program like F360 and then just exporting your model as a DXF and importing that into FEMM 

It's quite clear that a large portion of the flux is crossing the windings placed at one end and so it would be expected that a foil conductor would have large induced eddy currents. To test if this is really a problem when operating at electrical typical electrical frequencies you would find in an electric motor I wound two rods with the same dimensions as mentioned above. One with round conductors and one with a foil conductor. The foil was cur to a width such that its CSA was the same as the round conductor and both had ten turns applied.






Using an AC BH tracer I thin applied a 1 kHz and 10 kHz sinusoidal current to the windings. The result:
AC BH loops
It's clear that at 1 kHz there is little difference in the shape of the BH loop while at 10 kHz they are quite distinct. This indicates that even under this worst-case scenario a 10 kHz frequency, which is well above the typical electrical frequency used by electric motors, is required to produce significant eddy currents in the foil conductors. 

This suggests that for an electric motor, which will likely operate at a lower frequency and has less stray flux than this example, will not suffer from significant eddy currents in the conductors.

For a real BLDC electric motor, the flux crossing the conductors due to the relative movement of the magnets on the rotor must also be considered. This flux can be considerably larger than that induced by the stator windings alone. You can use this sheet to estimate the expected eddy current losses in a tape wound conductor. To edit the sheet just make a copy using the 'file -> make a copy' option.

3. Copper fill factor

It is desirable to have as high a copper fill factor as possible when constructing an electric motor so as to reduce the current density in the conductors so as to minimise `I^2R` losses. The copper fill factor is impacted by:
  • The stacking factor ( `P_{d}`): How efficiently a conductor is arranged in the slot.
  • The copper to insulation area ratio: A thick layer of insulation gives a low area ratio and a low fill factor.
As previously mentioned, round conductors have a fundamental stacking factor limit of ~0.9. Square and tape conductors can have a theoretical 100% stacking factor.


I imagine that it is this desire for a high stacking factor without the need to purchase expensive square conductors that convinced Shane to use tape wound conductors. 

Even though square and tape wound conductors can have a theoretical 100% fill factor, the copper fill factor (ratio of copper to total area) can never be 100% due to the need for an insulation layer in-between each winding. The thicker this insulation layer, the lower the copper (Cu) fill factor. Therefore the copper stacking factor is given by:

Cu fill factor` =\frac{CSA_{Cu}}{(CSA_{Cu}+CSA_{Ins})}\times `Stacking factor 

According to this site, a typical 24 gauge magnet wire has an insulation layer thickness of ~0.025 mm. For Shane's motor, he used a single polyimide (Kapton) tape, which has a typical thickness of 0.03mm, to insulate just one side of his copper foil.

Using this information I have estimated the copper fill factor when winding a conductor with a cross sectional area of 13.1 `mm^2` which is 2.54 mm wide, like that used by Shane's design. The spreadsheet can be found here.

Here are the results:
  • Round conductor: 88.5 % Copper fill factor
  • Square conductor: 97.3 % Copper fill factor 
  • Tape conductor: 94.5 % Copper fill factor 
This is quite a respectable copper fill factor and would only be superseded by the use of square conductors. Shane is therefore justified in his choice of a tape wound conductor.

However, one thing to note here is that the currents used by Shane's motor are unusually high, and his winding turn number is quite low. You will more typically encounter motors that have dozens to hundreds of turns and that operate at well less than 50 A. In this situation, a tape wound conductor may make less sense. 

A more typical motor that operates at < 50A with many turns per tooth

For example, if you wound a small motor with a tape conductor that has a cross-section equal to a 24 gauge conductor (0.5 mm diameter, 0.205`mm^2`) onto a 10 mm stator tooth your fill factor is as follows:
  • Round conductor: 75 % Copper fill factor
  • Square conductor: 80.8 % Copper fill factor 
  • Tape conductor: 40.6 % Copper fill factor 
All of the fill factors listed above are relatively low since the insulation layer is fixed while the motor size is reduced. The tape fill factor is also unacceptably small since the area per turn of the insulating Kapton layer at ~0.1 `mm^2` is now comparable to that of the copper foil itself at 0.2 `mm^2`.

To really drive this point home lets consider the copper fill factor of Shane's motor if he were to use lower currents and a higher number of turns, and therefore smaller cross section conductors.


If you were to halve the peak current of Shane's motor while maintaining the same current density (i.e. also halve the copper cross section) then it no longer makes sense to use a tape wound conductor. At this point, you are probably better off purchasing flat magnet wire or just sticking with round wire.

Additional points to consider:

User Kindiana over on the Odrive Robotics discord channel also pointed out that motor manufacturers are even less likely to be interested in tape wound conductors for the following reasons:
  • The extra weight and cost of copper is likely not worth the efficiency improvements at low torque for RC applications and is likely also why they don't stack windings closer together.
  • The tooling for machine winding foil may be far more complicated for a one piece stator compared to round wires or bundles of round wires.
  • There may be no readily available source of pre-insulated copper foils with custom dimensions, so manufacturers may need to do their own insulation.

Conclusion

At first glance, a tape wound conductor may appear as an attractive means to increase your electric motors copper fill factor without the need for expensive square conductors. However, when you look at the numbers more closely it becomes apparent that the high aspect ratio of a tape wound conductor will likely result in a worse fill factor for most applications. Furthermore, when a tape wound conductor is made quite thick then you will likely encounter considerable induced eddy currents in the conductor itself. Therefore careful consideration is required before you decide on a conductor geometry for your electric motor.

Equations were produced in this post with the help of arachnoid.com. If you have noticed any errors in the above article then please let me know.