Basic BLDC (PMSM) efficiency and power loss estimations

2025 Update:  Many of the charts used in this post were interactive through Plotly Chart Studio, which has now shut down. The plots are therefore now static. 

Electric motors exist to convert electrical power into mechanical power as efficiently as possible. In this post, a relatively simple analytical approach will be used to estimate the efficiency and power loss of a typical brushless BLDC (PMSM). This will be achieved using easily measurable motor parameters such as the winding resistance, torque constant and stator mass.


But first, a short and simplified overview of power losses in brushless electric motors. 

Simplified overview of power losses in brushless electric motors


There are many sources of power loss in an electric motor. However, they can generally be classified into three categories; core losses, `i^2R` losses and losses related to friction.


  • Core losses
Core losses typically refer to hysteresis losses and eddy current losses within a motor. Hysteresis losses occur anywhere that there is a changing magnetisation within ferromagnetic materials such as the stator laminations and the rotor back iron. Eddy current losses can occur anywhere within the motor where there is a changing magnetic field with time and something conductive. These eddy currents are mostly located in the stator laminations, which experience the largest change in magnetisation but also occur in the rotor back-iron and within the rotor magnets. Core loss typically dominates at high speeds and at relatively low torque.
  • `I^2R` losses

This is the power lost in the stator windings (the armature) due to the intentional flow of current from the motor controller. This loss dominates at low speeds and high torque.
  • Frictional losses

Fictional losses can be used to describe the power lost in the rolling elements of the motor such as the shaft bearings. It can also be used to describe friction caused by the movement of air, also often referred to as 'windage'. This windage loss may be due to a shaft-mounted cooling fan or even just due to the movement of the rotor itself. For motors that do not include an integrated shaft-mounted cooling fan, this source of loss is relatively small. Also, with the exception of very high-speed motors, the losses within well-maintained bearings also tend to be relatively small. For this reason, frictional losses will be ignored in this post.

Please keep in mind that power loss in electric motors is a very deep topic and the above descriptions of loss is a very simplified understanding. However, this basic starting point is enough to let us explore how the power loss in a brushless electric motor can be estimated from a few simple parameters.

A simplified analytical model of brushless motor power loss


To use a real-world example, let's estimate the efficiency and power loss of a T-motor U8 pro. 


This motor was selected because its efficiency and power loss has already been mapped by Ben Katz over on his blog. This efficiency and power loss data will be used to evaluate the accuracy of the model described below.

To model the motor we need to know a few parameters:
  • Winding resistance = 0.19 Ohm (line-to-line winding resistance)
  • Torque constant = 0.075 N.m/A (uses current supplied to the motor, not the motor controller)
  • Pole count = 42 (number of magnets on the rotor)
  • Approximate stator mass = 0.065 kg (mass of just the iron-silicon steel laminations)
The stator mass was estimated by extracting the volume of the stator from this great CAD model of the U8 pro and multiplying it by the density of Fe-Si steel which is around  8 `text(g/)cm^3`. If you don't know the stator mass of your own motor, you can assume it is around 1/4 to 1/3 of the total motor mass.

Let's begin by defining the core loss and the `I^2R` loss of this motor.
  • Core loss estimation for a brushless motor
For simplicity, this model makes a few key assumptions regarding core loss:
  1. The only core losses are those located in the stator laminations. All other 'core losses' (within the back iron, magnets etc.) will be ignored.
  2. The magnetic polarization of the stator is due only to the magnetisation provided by the permanent magnets in the rotor. That is, the core loss is independent of the current and torque output of the motor. This is a fairly safe assumption as my own testing in FEA software suggests the core loss is only slightly impacted by stator current.
  3. The magnetic polarisation within the stator is constant everywhere, has a maximum of 1.5 T and a fundamental frequency equal to that of the motor's electrical frequency. In a real motor, the flux density at the surface of the stator (at the teeth) tends to be larger than in the yoke. Higher-order harmonics and current ripple also lead to additional core losses. However, these extra losses are also relatively small in typical brushless motors and so can be ignored.
All these assumptions mean that the core loss can be estimated purely from the speed at which the motor spins and the number of poles it has. The actual core loss in our motors stator can then be estimated by fitting published core loss data for iron silicon steel laminations. Using this fitting, and the motor parameters, we can produce a contour plot of core loss for every speed and torque value.

Using this model we can predict the core loss in the T-Motor U8 Pro and present it as a contour plot.
 


As expected from our simple model, the core loss increases with motor speed and is not impacted by the torque output.

Note that there is also a relatively easy way to check if this model is accurate for your motor using the steps below:
  1. Measure the no-load power draw (i.e. power draw of the motor when it is not connected to anything) of your motor controller when it is spinning the motor at zero RPM, max RPM and a few points in between. 
  2. Subtract the zero RPM power draw from the other values to mostly eliminate the motor controller switching losses.
  3. Fit the data to estimate the core loss for all points in between your measured values. 
You can find an example spreadsheet for this process here. This process works because almost all the power loss at high speed and no load is due to the losses in the core of the motor.

  • `I^2R` loss estimation for a brushless motor
To calculate the resistive losses of the motor we must know the current required to produce a given torque. This is defined by:

$$ Current (Ampere) = \frac{Torque (Newton.meter)}{Torque \,constant (Newton.meter/Ampere)}$$

Remember that the current referenced here is the line-to-line current supplied to the motor and not the current supplied to the motor controller. You can estimate the torque output of your motor from its velocity constant. With the current and winding resistance known the power loss for each torque value and velocity can also be mapped.

Also as expected, the `I^2R` power loss is completely independent of the motor speed. In reality, `I^2R` loss would increase slightly with speed and torque due to skin/slot effects and core saturation respectively.

With the core loss and `I^2R` data now computed, we have all that we need to calculate the input power, output power and efficiency of our motor.
  • The combined power loss of the motor
The core loss and the `I^2R` loss can now be combined to estimate the total power loss of the motor.



It is clear that the power loss is largest at high speed and high torque. Lets now move on to the power output, power input and efficiency. 

  • Motor power output and power input mapping

The mechanical power output is estimated by the following:
$$ P_{out}= Torque (Newton.meter) * Angular\, Velocity (Radian/second)$$
where $$\omega = \frac{RPM}{60} 2 \pi$$
Unsurprisingly, when plotted we can see that the motor produces peak power at the highest torque and speed. 
 

The Input power to the motor is then given by:
$$ P_{in}= P_{out} + P_{loss}$$
 
 

From this, we can now estimate the motor efficiency and map it.
  • Motor efficiency
The efficiency (`\eta`) of an electric motor is defined as the useful mechanical power output  (`P_{ou\t}`) divided by the total power input (`P_{i\n}`). The input power is in the form of a voltage (`V`) and current* (`I`) while the useful mechanical power output is in the form of torque (`\tau`) and angular velocity (`\omega`) as defined by the following:
$$\eta  = \frac{P_{out}}{P_{in}} = \frac{\tau \omega}{V I} $$
Using the power input and output we have already calculated the motor efficiency can be estimated and mapped.
 


So how does this simple model stack up when compared to the measurement of a real motor? Below is the motor efficiency and power loss. Note that 180 rad/s is equal to approximately 1700 RPM and so the x and y-axis ranges are equivalent.


The first thing to note is that the top right-hand corner of the measured efficiency map is missing due to limitations in the supply voltage for the motor controller. More info on why in this post. The next important difference between the model and real data is that the numerical model predicts a far more efficient electric motor. The peak motor efficiency that was measured on the real motor was around 70% while the model predicts a peak efficiency as high as 85%. The peak efficiency region also extends to a much lower RPM and torque value than the measured efficiency map.

There are two likely reasons for this overestimation in motor efficiency:

1. The core loss is underestimated in the model. The core loss used in the model is measured for flat sheets of iron silicon steel placed in a test jig. In a real motor, the sheets are stamped, compressed and then welded to form a stacked core. These processing steps can reportedly increase the core loss by a factor of 2 to 3. Therefore a 'core loss fudge factor' of 2.5 was included in the model to help compensate for this.

This reduced the peak motor efficiency to be more in line with that of the real motor. However, the 70% efficiency contour line extends to a much lower speed range than the real motor efficiency map. This may be due to:

2. The measured motor power loss also included the power loss in the motor controller. This extra loss would be seen in the form of a slight increase in the I^2R loss and, perhaps more importantly for the efficiency map, the addition of a fixed power drawn by the motor controller at all times. This is the 'always on' power draw of the motor controller that is independent of the current it is supplying. It can range from less than 1 W in small motor controllers to >10 W in high-power versions. I don't know the power draw of the motor controller used in the testing and so I have just assumed a value of 8W. The resulting efficiency map is shown below.
  
With this change, the modelled efficiency map of the T-Motor U8 Pro now more closely resembles the measured efficiency map. This is because at low speed and torque, the motor is producing very little power. Therefore, if you add a small power loss of ~8W it can greatly reduce the system efficiency in this region. 

Conclusion


Some may be quick to point out that if you play with the numbers and assumptions long enough you could make an efficiency map look any way you want. However, in my opinion, the assumptions made in the model above, which are based on my experiences and observations both with real motors and simulated motors, cover the majority of the losses within a typical 'hobbyist' grade brushless motor. While this simple model is most definitely an oversimplification of a complex system it can still provide a good insight into the major sources of power loss and how they dictate the efficiency of a motor. So I encourage you to have a play with the numbers (i.e. pole count, winding resistance etc.) using the Jupyter notebook mentioned below to help improve your understanding of how aspect each impacts motor efficiency with speed and torque.

Equations were produced in this post with the help of arachnoid.com/latex/. Figures were produced using Plotyl and hosted on Chart Studio. Online Jupyter environment using Binder. If you have noticed any errors in the above article, then please let me know.

Friday, July 12, 2019

BLDC (PMSM) end turns and torque production

Jan 2020 update: I have removed the discussion of end turns in iron-core motors from this post as I have since learned that the arguments used were flawed. I will address this topic in my next post.

End turns are not considered when calculating the torque of a hobbyist grade BLDC (PMSM) electric motor. This post explores why.

1.End turns and BLDC motors

End turns are the region of a BLDC motor's windings which extend out from the slots at either end of a motor.
Current supplied to a motor passes from one slot to the next via the end turns. However, end turns are not typically considered when calculating the torque produced by a BLDC motor in 2D FEA software packages such as FEMM.

Although end turns can be ignored when it comes to calculating torque, they do contribute to the resistance of the windings. It is therefore ideal to have the end turns be as short as possible when designing a motor so as to improve motor efficiency by minimising ohmic losses in the windings.

Electric motors with concentrated windings, like those found in most hobbyist outrunners, have shorter end turns than those used in motors with distributed windings. Motors that use concentrated windings are therefore more efficient in some use cases, such as in high torque density, low-speed applications. However, as only a limited number of slot and pole combinations are available for concentrated windings they are not suitable for all use cases.

2. Torque generation and end turns in core-less motors

To understand why end turns are not considered when calculating the torque output of a BLDC motor let us consider a simplified scenario. In the diagram below a single turn copper wire is placed inside a homogenous magnetic field provided by permanent magnets placed above and below the wire. The magnets are arranged so that the applied field direction is different for either side of the wire.

This situation is an analogous to core-less electric motors which have no ferromagnetic material in the stator. If a current flows through the wire then a Lorentz force is produced on that wire as described by:

Force = Magnetic field `\times`Current`\times` Conductor length

where the magnetic field (B) is supplied from the magnets, the current (I) is that flowing through the wire of a given length (L). Looking at this setup from the top down we see the following.

It is clear that a Lorentz force is only generated on the wire which is located between the magnets, which is analogous to the wire located within the slots of a BLDC motor. The parts of the wire which extend outside of the magnets are not exposed to a magnetic field and so the force generated is zero. This situation is the same for end turns in a BLDC motor, and so is ignored by FEA software packages.

However, for the sake of argument, let us also consider a situation where the magnets could be made long enough that they also covered the end turns. In this situation, a force is generated by the end turns. However, this force is tangential to that generated by the wires in the 'slots' and so would not contribute to the production of useful torque within a motor. This force would also be mostly cancelled out as can be seen from below.

Another arrangement I have seen used by DIY motor makers is to take round coils and magnets and arrange them to make an axial flux motor or generator.



While this approach will work, it is also inefficient since the force produced on the wires is always tangential to the flow of current and so a significant fraction of the force is not available to useful work.

Note that although all of the above examples are for core-less motors, the situation is unchanged for iron cored motors.

In my next post, the concept of flux linkage will be explored and used to understand why end turns still do not contribute to flux in conventional iron-core motors.

4. Conclusion

End turns in air-core motor designs are not considered in the calculation of torque as they are either outside of the region exposed to the permanent magnet's magnetic field or the force generated is in the wrong direction.

Equations were produced in this post with the help of arachnoid.com. If you have noticed any errors in the above article then please let me know.

Saturday, February 9, 2019

How to model a BLDC (PMSM) motors Kv (velocity constant) and Kt (torque constant) in FEMM

In a previous post, the velocity constant (Kv) and torque constant (Kt) was estimated for a number of different 'hobbyist level' BLDC (PMSM) out-runner motors. In this post, I will be using FEMM to model one of these motors as accurately as possible. In the process, you will see how to use FEMM to model such a motor and how accurately its results compare to the real thing.

Measuring key parameters prior to modelling

Before the motor can be simulated in FEMM we first need to determine its key parameters. The motor to be simulated is an Odrive Robotics N5065 motor which has previously been characterised in this post. Note that this motor is a pre-production unit that was sent to me for testing by Oskar of Odrive Robotics and differs slightly (5mm shorter stator, different winding number) from that offered in his shop today.

The key motor parameters are:
  • The number of slots in the stator and the number of poles in the rotor
In order to make this, and the following steps, easier the motor was first disassembled. Disassembly was achieved by the removal of a single circlip from the shaft and pulling the rotor bell away from the stator. Some force is required due to the attraction of the magnets to the stator iron. 


With the rotor bell removed it was simply a matter of counting the number of slots/teeth on the stator and the number of magnets on the rotor. This motor has 12 slots and 14 poles (12n14p). The likely reason that the manufacturer chose this number of slots and poles is explored in detail here.
  • The stator lamination dimensions and tooth profile
The stator lamination dimensions and tooth profile can be difficult to measure directly. If you don't mind destroying your motor then you can remove all the windings and separate a single stator lamination (or just section the entire motor with a slow speed saw) and use a flatbed scanner to capture the dimensions of the lamination without any perspective errors. Including a ruler when scanning will allow you to set a correct scale. Then you could use a software package with edge detection (such as Inkscape, which is free) to produce a DXF file without the need for any other CAD software.

In my case, I didn't want to destroy or unwind the motor and so I instead opted to model it as best I could in F360 (free for hobby/student use) and then export the sketch as a DXF file for FEMM. By doing this in with parametric design software like F360 it also allows me to play around with motor parameters in future without the need to start from scratch.

The sketch was started with the inner and outer diameters and then a single tooth and its windings were added. This tooth was then copied using the 'circular pattern tool' to make a full stator. 

F360 sketch of the stator
While this method is far from ideal it does give a good approximation as we shall see.
  • The rotor magnet dimensions and grade
The magnets are glued to the rotor bell with epoxy and are also held at the correct separation by segments machined into the end cap and also into an aluminium retaining ring at the open end of the rotor bell.

The silver magnets are retained in the black rotor bell with the grey epoxy and the silver coloured aluminium ring in the open end
This approach gives good retention of the magnets but does make it difficult to estimate the actual thickness of these magnets. I made my best approximation by taking the outer bell diameter and the inner flat-to-flat measurement of the magnets and assuming the rotor bell thickness (the black walled region in the image above) is constant. Using this data, and the assumption that the magnets are flat and not curved the rotor was also modelled in F360.

F360 sketch of the rotor
Since the magnets are assumed to be perfectly flat and are glued to the inside of a cylinder there is a small 'air space' (actually filled with epoxy) below the magnets. When I imported this sketch as a DXF into FEMM later these small gaps were removed by FEMM. If you wish to maintain them for accuracy then you can force FEMM to recognise them by including a small line segment between the rotor bell and the magnet that crosses the thin air gap region.

 The magnet grade specified by the motor manufactures is N42. If you don't know the magnet grade of your motor then you can make a fairly safe guess by assuming N35 if its a cheaper model or N42 if its a higher end model. As there was in no material option in FEMM for N42, I went with N40 instead. In my case, FEMM suggests that using over N40 over N35 grade magnets leads to a ~7% increase in torque.

The rotor and stator sketches were exported as DXF files ready for importing into FEMM. You can find a copy of DXF files here. Note that FEMM doesn't know the difference between 'construction' geometry generated by F360 and normal sketch lines and so you may want to remove them before exporting as a DXF file.
  • The diameter of the wire used, the turn number per tooth and the number of parallel strands
Since I didn't want to unwind the motor it was difficult to determine the number of strands and turns per tooth used. Isolating a single strand and measuring it with a calliper suggested the diameter to be around 0.35 mm and so the diameter of the wire without copper insulation was assumed to be 0.34 mm.

The number of parallel strands was estimated by isolating a segment of wire running from tooth to tooth and poking it with a pen until most of the individual strands were visible. 


I count a total of 8 strands. Luckily for me, the number of turns per tooth (ten) was written right on the side of the stator stack.


However, it should be possible to estimate the number of turns with a reasonable margin of error from the winding resistance of the motor and the wire diameter if needed.
  • The method of winding (i.e. star or delta)
In my previous post, I had assumed that this motor is star wound. This turns out not to be the case. As can be seen in the image above one of the leads coming from the motor has 16 parallel strands. This suggests that the motor is delta wound, with the ends of each phase winding (8 parallel strands) grouped together with the next phase for termination to give a total of 16 strands. This was further supported by the fact that that I can't see any region in the motor where a required join would be made for the natural point of a start wound motor. It is likely that all of the motors I previously look at are delta and not star wound.

Other motor parameters include the lamination thickness, the lamination hysteresis loss, skin and proximity effect of the windings, friction of the bearings etc. can be ignored here as we are only considering the motor under static conditions.

Modelling a motor in FEMM

Getting started with FEMM is fairly straight forward if you can look past its outdated interface. Before starting the motor simulation below I would highly recommend following this quick tutorial so that you are familiar with the interface first.

When ready to model your motor, start a new magnetics problem. From the menu bar select 'problem' and check that you are using the correct units with respect to your DXF file and that have set up a planar simulation. You will also want to check that the 'depth' of your simulation matches the length of your rotor. In this case, my rotor was 30 mm long.



The next step is to import your DXF file(s) using the file -> import DXF option. This can take some time depending on the amount of geometry. If you have any 'construction' lines left over from your CAD model now is also time to remove those. Note that it is also important that the centre of your model be located at point (0,0) for torque estimation to be conducted later.



With your geometry imported its now time to assign material properties. In my case, the rotor bell was assumed to be M-22 Fe-Si steel which is inaccurate. I should have used hot rolled low carbon steel or similar. However, this is unlikely to have had a large impact on the results. The shaft was selected as hot rolled low-carbon steel. The laminations were chosen as M-22 Fe-Si steel which is a common grade used for electric motors.

Magnet placement was done using the Lua scripting language, which is natively supported by FEMM. You can find a copy of the script I used here. Simply enter the number of poles, the radius at which the magnets can be found and the angle (0 degrees being horizontal) that the first magnet can be found. The script will then place each material assignment at the correct orientation. If you wish to change the magnet grade just change the name of the block property in the script (i.e. "NdFeB 40 MGOe")  to that of the magnet you wish to use from the list in FEMM.

The windings were then assigned based on the number of turns and the number of strands. In my case, I created a new 'block property' using the property definition dialogue box. In this case, I selected plain stranded wire with a 0.34 mm diameter and 8 strands and then assigned the same properties used by the other copper conductors.


The actual order which the windings were placed was determined using this handy winding layout tool. By selecting 12 slots, 14 poles, two-layer winding (single winding per tooth as opposed to a single winding for every second tooth) the following is seen.



Using this as a template the winding phase and direction (either into or out of the page) was assigned. This was the most tedious process of creating the motor in FEMM. With all the materials properties assigned we see the following.
The regions filled by air were assigned (one for the air gap region inside the rotor bell and one for outside the motor) and the open boundary builder (circle within a circle button) was used to set the boundary conditions and default settings are fine here.


Finally, we need to set how much current is supplied to each winding. Since this motor is driven using field oriented control (FOC) we need only supply a current to one phase and a current opposite in sign, and twice as small, for the other two phases as per the figure below.


In addition, this motor is delta wound and so the current supplied to the phase will be equal to square root(3) of the line current as described here. In my previous post a phase current of 40 A produced a torque of 1.2 N.m. However, this value of 40 A is the line current (or phase current for a star wound motor) and so we need to divide that value by sqrt(3) to get the phase current that our delta wound motor saw. This gives a value of + 23.1 A for phase A, and - 11.55 A for phase B and C. These values are set in the circuit dialogue box with a series connection.

With this, the motor is now ready for simulating. The complete FEMM file used can also be found here. Note that in order to run this script the minimum angle setting (Problem -> Min. Angle.) needs to be set to 20.

Torque constant estimation

The torque constant (Kt) of an electric motor can be estimated using FEMM with only a single simulation. However, you will want to make sure that your rotor is rotated so that it will produce its maximum torque per amp. In this case, peak motor torque is given when the rotors d-axis is 90 electrical degrees (360 electrical degrees is equal to 360 mechanical degrees divided by the number of pole pairs, which in this case is 7) ahead of the q-axis. A simpler 6n8p motor schematic below for illustration purposes.


Simulating the 12n14p N5065 motor with the rotor 90 elec. degrees ahead of the d-axis looks like the following.



To determine the torque produced the rotor needs to be selected using the area selection tool (green box inside four points) by clicking on each of the magnets and the back iron as shown below.


With rotor selected we can find the torque around point 0.0 using the integrate option and 'Torque via Weighted Stress Tensor' selection from the drop-down menu as recommended in the FEMM manual.


The result is a torque of 1.37 N.m.


For reference, the real motor measured 1.2 N.m. Therefore the FEMM value is an overestimation of about 15%. Considering the number of assumptions made with this model I was actually surprised that the FEMM estimation is as close as it is.

Kv, back EMF estimation

The back EMF constant (Kv) can be estimated using only the torque constant and the motor current as described in this post. In this case, our line current of 40 A and FEMM modelled torque of 1.37 N.m gives

$$K_{V} \approx \frac{8.3 \times 40 }{\tau } \approx 242$$

The listed Kv of this motor was 270 Kv and so once again we are only off around 15 %.

In order to estimate the shape of the back EMF we need to do a series of simulations at different rotor angles and plot the torque output. This torque output can then be converted to Kv in the same way as shown in the equation above. In order to automate the rotor incrementing process, I used a Lua script which can be found here.  In short, it rotates group one by x degrees around point 0,0 and solves. At the completion of solving it prints the torque around point 0,0 to the console and takes a screenshot of the resulting output. Thefeore the use of this script means that you need to assign each line segment and materials property of the rotor to group one as is shown in this video. Don't forget to copy the contents of the console output into another file and the completion of your simulation or otherwise modify the script to output data to a file. To use this script, place it in the same folder as your motor's .femm script so that your file is listed in line 8 "open(mydir .. "Your file name here.FEM")". You can also set how many steps you wish to make and how many degrees of rotation you desire.

Note that solving for each position may take up to 30 seconds and so running hundreds of steps will take many hours to complete. Doing this for the D5065 motor model we see the sinusoidal torque output with rotor angle below.

This sinusoidal torque with rotor angle, and therefore back EMF as they are the same thing, agree well with the back EMF seen for this motor.




Using the excellent, and free, OBS studio in 'slide show' mode was also able to stitch all the separate solutions .bmp files that my script outputted and create this clip of the flux distribution for different rotor angles.


Cogging torque estimation

The cogging torque (torque due to the attraction of the rotor magnets to the salient teeth of the stator) was estimated using the same method as the Kv estimation. The key difference being that the armature current was set to zero and a much finer step was used. The figure below shows the raw output data in black which is quite noisy and an FFT smoothed fit of the data in red.


As discussed in the last post, the number of cogging steps per rotation is given by the least common multiple (LCM) of the number of stator slots and rotor poles. The LCM of this 12n14p motor is therefore 84. A quick count of the peaks in the smoothed data above and extrapolated out to 1 rotation (360 mechanical degrees) and a cogging frequency of 84 is confirmed. As will be discussed in more detail in a future post, the cogging torque amplitude depends strongly on magnet placement, magnet shape, stator tooth shape etc. and so the magnitude and shape of your cogging torque estimated be FEMM will only be accurate if you have modelled your motor exactly.

Modelling motors with symmetry

While it is not shown here, it is important to point out that it is often not necessary to model an entire motor to determine its properties. For motors with symmetry you may only need to model a small segment of the motor and from that, you can extrapolate the results of a full-size motor. There are also a few different tools available in FEMM that may be worth exploring.

Alternatives to FEMM

As can be seen from the results above FEMM is capable of approximating some properties of an electric motor. However, there are many alternatives that are also worth considering. If you would like to use FEMM on platforms other than windows then take a look at the xFEMM project. While xFEMM does away with the user interface it is also considerably faster (up to 80x in some instances) and is still a free open source.

If you require simulations of 3D bodies or more complicated AC loss analysis etc. then you will need to move on to an expensive commercial FEA package such as the Maxwell from Ansys or Comsol Multiphysics. 

Conclusion

Modelling an electric motor in FEMM is no easy undertaking. However, by carefully replicating all of the required components it is possible to get a reasonably accurate estimation of a motors Kt, Kv, back EMF shape and cogging torque parameters. Kt and Kv was shown to be within about 15% of that measured for a real motor and so FEMM can act as a nice starting point for verifying ideas when designing an electric motor.

Sunday, January 27, 2019

Selecting the best pole and slot combination for a BLDC (PMSM) motor with concentrated windings

The full spreadsheet used in this post is available for download. To modify the sheet just choose the 'Make a copy option' from the drop-down file menu.

Introduction 

Concentrated windings have a single coil per tooth and are commonly used on 'hobbyist' style BLDC (PMSM) out-runner motors.

A key advantage of concentrated windings is that they can be quickly and cheaply wound by machine as seen in the video below.


Even motors with very thick conductors can be wound by machine.


Other advantages include short end turns, which do not contribute torque to the motor and only increase the winding resistance, and space for effective air cooling. A major drawback of concentrated windings is that without careful consideration of the stator slot number and rotor pole number the performance of the motor will be poor.


This post will examine the advantages and disadvantages of different slot and pole combinations. The information is based off the paper 'Distribution, coil-span and winding factors for PM machines with concentrated windings' by S.E Skaar et al. and the book 'Design of Brushless Permanent-magnet Machines' by J. R. Hendershot and T. Miller. See the 'recommended reading' list above for more information on this book. The emotor.com glossary page is also useful for reference.

The winding factor

An electric motors 'winding factor' (not to be confused with its copper fill factor) is a number between 0 and 1 which represents the fraction of the armature current which is used to produce torque.

From emotor.com's glossary page the winding factor is defined as the following:
The winding factor for a specific winding expresses the ratio of flux linked by that winding compared to flux that would have been linked by a single-layer full-pitch non-skewed integer-slot winding with the same number of turns and one single slot per pole per phase. The torque of an electric motor is proportional to the fundamental winding factor.
Despite being so fundamental, the calculation of the winding factor is not often discussed in textbooks. I found that the paper mentioned above has the easiest to follow description, although I had to rely on the emotor.com description of an unbalanced winding as the solution provided in the paper appears to not cover all scenarios.

I will not be going into detail about the calculation of the winding factor. However, you can find the spreadsheet used to calculate the values shown in this post here. This spreadsheet includes up to 108 slots and 70 poles and is easily extended further where needed.

The winding factor for a 3 phase machine with a non-skewed rotor can be seen listed in the table below where the top row is the number of poles and the left-hand column is the number slots. Since this is a three-phase machine the number of slots increases by three and since a magnet has two poles (a pole pair) the pole number increases by two.


It can be seen that some slot and pole combination have a winding factor of one while others are approaching zero, or even negative. However, not all of these slot and pole combinations can be used as is described below.

1. Exclude windings where q < 0.25

The slot to pole ratio with consideration for the number of phases is designated by the variable q. If q is less than 0.25 then the arc covered by a rotor pole is now less than half a stator tooth. This results in multiple north and south magnet poles interacting with each stator tooth and so the torque generated by the motor is reduced. Therefore, q values of less than 0.25 are generally not considered feasible and can be eliminated. The images below were created with this winding layout tool. Note that in reality, the gap between each stator tooth would be much smaller.

Example winding layouts that give a q value that is not considered feasible.

The calculated q-values for different slot and plot combinations.

The winding factor of each slot and pole combination with those combinations that give q<0.25 removed.

2. Exclude windings where q > 0.5

Alternatively, if q is greater than 0.5 then it no longer makes sense to use a concentrated winding as a single rotor pole will span over multiple teeth. Instead, a distributed windings would be used. Therefore, these combinations can also be excluded for our purposes.



3. Exclude windings where Ns = Nm

If the number of slots (Ns) is equal to the number of poles (Nm) then the motor will produce large cogging torque and will no longer be self stating. This combination can therefore also be eliminated.


4. Removal of unbalanced windings and motors without symmetry

A motor with balanced windings will have the same number of coils for each phase per repeating segment of the motor. A motor must have balanced windings for operation. More information here. 


Also, it is ideal to have a motor that has a symmetry of at least 2 (i.e. the motor has two repeating sections) as this helps avoid unbalanced radial forces and noisy operation. In other words, a motor without any symmetry will produce its torque on only one side of the rotor. If a motor has a symmetry of two then its torque will be produced on opposite sides of the rotor, balancing the forces.

The slot and pole combinations that produced unbalanced windings and no symmetry can, therefore, be eliminated.


Based on the table above it can be seen that 12s10p and 12s14p are attractive combinations. This explains why these slot and pole combinations are so popular for 'hobbyist' out-runner electric motors.

5. Consideration of cogging torque

In addition to the winding factor, cogging torque is also an important consideration. Cogging torque creates vibration and noise during operation and acts to disturb the motor away from its desired position when used in servo applications. The cogging torque frequency is also closely correlated with the production of rotor losses both with and without current supplied to the armature.

The cogging torque frequency is given by the least common multiple (LCM) of the stator slots and the rotor poles. The figure below displays the possible slot and pole combinations with the winding factor replaced with the cogging torque frequency. 


Selecting as high a cogging frequency as possible is desirable as it reduces the amplitude of the cogging torque. With this in mind, 24s22p would be an attractive option with its 264 cogging steps per rotation and 0.949 winding factor as opposed to only 84 cogging steps per rotation for 12s14p.

6. Higher order harmonics

So far we have only been considering the fundamental winding factor. However, different slot and pole combinations also affect the winding space harmonics. This topic will be covered in more detail in a future post once I have a better understanding of the topic.

7. Additional considerations

From the last two tables above its easy to conclude that a 24s22p motor is 'better' than a 12s14p motor since it has both a higher winding factor and a higher cogging frequency. However, there are other factors that also need to be considered.

7. 1 Maximum electrical frequency

The electrical frequency (current sine-wave supplied to each phase) scales linearly with the number of pole pairs (Nm/2) of a motor. Therefore, doubling the pole count of a motor will increase its core losses by a factor of four since it scales with the square of the electrical frequency. Doubling the pole count will also double the back EMF produced and so twice the required voltage will be needed to drive the motor at the same RPM. However, rewinding of the motor with a lower number of conductors per tooth can be used to offset this increase in the back EMF and will not impact the efficiency of the motor. In addition, reducing the lamination thickness will help minimise eddy current losses, which scale with the square of the lamination thickness. See this spreadsheet for more details. At the extreme, the switching frequency of the motor controller used to drive the motor may also need to be increased in order to maintain a good approximation of a sine wave. This will incur additional dead time losses in the motor controller. 

The electrical frequency required to operate the motor at 10,000 RPM is shown below.


7. 2 Mechanical winding considerations

Trying to squeeze more slots into a small motor is not always possible. Increasing the number of slots while keeping the motor diameter the same typically means that multiple smaller conductors must be used in order to bend around the tighter radii and make use of the available space. Smaller conductors have a larger fraction of their total cross section taken up by insulation and so the copper fill factor of the motor can be reduced even if the winding factor is increased. A lower copper fill factor means a higher current density in the winding and so higher I^2R losses.

7. 3 Cooling considerations

Effective cooling is critical for a high power density electric motor. Having a large number of slots and small conductors may congest the air flow path and reduce air cooling effectiveness. This, in combination with higher core losses due to an increase in the electrical frequency, can reduce the power density of a motor.

7. 4 Tooth-tip leakage

Squeezing more slots into a motor may also require that the gaps between the teeth be reduced. Reducing the size of this gap can allow some flux to jump (or zig-zag) from one tooth to the next, reducing the effective torque produced by the motor.

7. 5 Rotor skewing

If you plan on skewing your motor in an effort to reduce its cogging torque then it is important that the required skew does not lower the winding factor too much. The reduction in the winding factor is given by the skew factor discussed here. This topic will be covered in more detail in a future post.

7. 6 Reduced rotor and stator back-iron (yoke) mass

Increasing the pole and slot count of an electric motor has the advantage of reducing the flux density in the back-iron. This is because the higher number of stator slots and rotor poles means that flux does not need to travel as far around the stator or rotor to make a closed magnetic path. For every doubling of the pole or slot number, the flux density is halved and so the thickness, and therefore mass, of the back-iron can also be halved. This acts to increase the power density of the motor. 

For example, Siemens appears to have increased the gravimetric torque density (torque per unit mass) by 50% for their 260 kW light aircraft electric motor by increasing its pole and slot count from an already high 36s30p to 72s60p. Note that this assumption is based solely on the images from their promotional material.

Conclusion

The tables above provide guidance when selecting the number of slots and poles for a BLDC (PMSM) motor with concentrated windings. If the diameter of your motor is less than approximately 60 mm and if your maximum RPM is less than 10,000 then 10s14p or 12s14p may be a good choice. For larger diameter and/or motors that rotate more slowly a higher slot and pole count can be used, such as 24s26p with a reduced number of turns per tooth and thinner Fe-Si laminations. Higher pole count motors will have a higher electrical frequency, increasing losses, but will also have a lower mass since a reduced back-iron thickness can be used while also having a smaller cogging torque amplitude.